Process Flowchart

From QPR ProcessAnalyzer Wiki
Revision as of 15:28, 16 November 2021 by Ollvihe (talk | contribs)
Jump to navigation Jump to search

Flowchart visualizes the eventlog as process flowchart, where the boxes represent the event types (activities) and the arrows are flows (transitions between consecutive events). Flowchart also shows selected measures calculated for the event type and flows, such as case/event counts, durations and costs. The visibility settings of the Flowchart Analysis help to show only the most important event types and flows, and the ones which occur less often can be hidden.

Event types are shown as boxes. Event type name is shown as the first text line in the box. Event type measures mapped to Label, 2nd label and 3rd label are shown in the next lines. Flows are shown as lines connecting the event types. There is an arrow in the end of the flow to indicate the flow direction. Flow measures mapped to Label, 2nd label and 3rd label are shown in the middle of the line. The starting and ending flows are shown as dashed lines. When an event type is hovered, its incoming and outgoing flows are highlighted.

FlowchartAnalysis.png

Visibility settings

Usually the real-life processes are so complex that showing all event types and flows between them is not a very illustrative presentation. This is why the flowchart is able to show only the most important event types and flows based on the variations: You can choose the top number of most common variations, which are visualized as the flowchart, i.e. only the event types and flows that appear in those most common variations are shown.

There is a numeric box in the bottom left of the flowchart, where shown the top number of variations can be set. In addition, there are plus and minus buttons on increase and decrease the variations number. When the buttons are pressed, there is always a change in the flowchart. To achieve that, variations may need to be skipped, as they don't provide any more event types or flows to the flowchart.

Note that the visibility settings and filtering are different things: even though visibility is limited, the measures are calculated to the entire eventlog (not just the for the shown variations).

Zooming and filtering

Event type and flow based filter rules can be created from the flowchart by selecting them. When selecting only event types, you can create a filter which includes and excludes cases containing any the selected event types. In addition, you can include and exclude the selected event types. When selecting only flows, or event types and flows, you can create filter to include cases containing the selected flows and event types.

The flowchart can be moved with the mouse dragging (i.e. keep left mouse button pressed while moving the mouse cursor). Use the mouse wheel to zoom in and out while cursor is over the flowchart. You can also use the + and - buttons on the bottom right corner, which increase and decrease the zoom level by 10% in each step.

There are two types of resets for the zoom and position: Window width and 100% zoom. The two resets can be toggled by clicking the Reset zoom button in the bottom right. When zoom is 100%, Window width mode is activated, and when zoom is other than 100%, 100% zoom mode is activated.

Event type and flow KPI's

Flowchart is able to show and visualize measures for event types and flows. For event types, the following visualization mappings are available:

  • Color: Event type box background color is determined based on this measure. The lowest available value gets the lightest blue, the highest value gets the darkest blue, and other values get scaled colors between the extremes.
  • Label: Measure value is shown below the event type name in the event type box. There can be several measures mapped to this, which are shown in the same line separated by a pipe (|) character.
  • 2nd label: Measure value is shown below the Label. Like the Label, there can be several measures mapped to this.
  • 3rd label: Measure value is shown below the 2nd label. Like the Label, there can be several measures mapped to this.

For flows, the following visualization mappings are available:

  • Flow thickness: Flow line thickness is determined based on this measure. The lowest available value is shown as the thinnest line, the highest value is shown as the thickest line, and other values with thicknesses between the extremes.
  • Color: Color of the flow line. The lowest available value is shown as the lightest gray, the highest value is shown as the darkest gray, and other values get scaled colors between the extremes.
  • Label: Measure value is shown in the middle of the flow. There can be several measures mapped to this, which are shown in the same line separated by a pipe (|) character.
  • 2nd label: Measure value is shown below the Label. Like the Label, there can be several measures mapped to this.
  • 3rd label: Measure value is shown below the 3nd label. Like the Label, there can be several measures mapped to this.

Visualize KPI's with conditional formatting

For details how to define conditional formatting, see the tables. For conditional formatting of event types, the following formatting types are available:

  • backgroundColor: Color of the event type box background.
  • borderColor: Color of the event type box border.
  • textColor: Color of the texts in the event type box.

For conditional formatting of flows, the following formatting types are available:

  • color: Color of the flow line.
  • textColor: Color of the flow measure texts.

Example of event type background color (green when >10000, yellow when 5000-10000 and red when <5000). Add the following code to the conditional formatting of the event type measure that determines the background colors:

{
  "backgroundColor": {
    "rules": [
      {
        "color": "#EF5254",
        "value": 10000,
        "comparison": ">="
      },
      {
        "color": "#FFD851",
        "value": 5000,
        "comparison": ">="
      },
      {
        "color": "#68DD8F"
      }
    ]
  }
}

Flowchart settings

Flowchart settings can be opened by clicking the flowchart so that it gets selected, and then clicking the settings button on the top right of the flowchart. Flowchart has the following settings in the General tab:

  • Diagram initial zoom: Zoom level used when the dashboard containing the flowchart is opened. Available options:
    • Window size: Flowchart fits to the visible screen entirely while being as large as possible.
    • Window width: Flowchart width takes the entire area width. If height is greater than area, the top part of the flowchart is visible. In other case, flowchart is positioned vertically in the middle of the canvas.
    • 50/80/100/120/150/200% zoom: Flowchart zoom level is set to the defined percentage and top of the flowchart is aligned with the top of the canvas. If this would lead to empty space below the flowchart, position the flowchart in the center of the canvas instead.
  • Exclude hidden event types in calculation: When enabled, hidden event types are excluded from the event type and flow measures calculation. This is done by adding an include only event types filter rule for the visible event types, to all event type and flow measure calculations. This behavior affects especially the flow measures calculation, because not visible event types are excluded and flows go the visible event types.
  • Show event type names: Shows or hides event type names that are visible in the event type boxes.
  • Highlight incoming and outgoing flows: When enabled, incoming and outgoing flows are highlighted when an event type is hovered with the mouse.
  • Allow multiselect event types and flows: When enabled, several event types and flows can be selected at the same time. When disabled, only one event type or flow can be selected at a time.
  • Allow zooming flowchart: Zooming the flowchart is allowed (using the mouse wheel and the zoom buttons). When not allowed, the zoom controls are not visible.
  • Allow moving flowchart: Moving the flowchart in the canvas is allowed (using the mouse drag).

The Layout tab has the following settings:

  • Show legend: The legend, explaining the event type and flow measures, is shown in the top left corner of the flowchart.
  • Show variation stepper: Variation stepper, to set the shown number of event types and flows, is shown in the bottom left corner of the flowchart.
  • Show zoom buttons: Zoom controls are shown in the right bottom corner of the flowchart.
  • Start/end symbol color: Color of the process start and end symbols in the flowchart.